DSC PC15OO Installation Manual

Browse online or download Installation Manual for Security access control systems DSC PC15OO. DSC PC15OO Installation manual [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Installation
Manual
PC15OO
W A R N I N G
This manual contains information on limitations regarding product use and
function and information on the limitations as to liability of the manufacturer.
The entire manual should be carefully read.
Software Version 4.1
DLS-1 V6.5 and up
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - Installation

InstallationManualPC15OO• W A R N I N G •This manual contains information on limitations regarding product use andfunction and information on the limi

Page 2

6To Bypass Zones:Enter [∗][1] - the “Bypass” light will start flashing.Enter [zone number to be bypassed]; the zone light will comeON to indicate that

Page 3 - TABLE OF CONTENTS

7Programming Access CodesEnter [∗][5][Master Code] to enter the access codeprogramming mode. The “Memory”, “Bypass” and “Trouble”lights will begin to

Page 4 - HOOKUP DIAGRAM 29

8Bell Test[∗∗∗∗∗]+[6]+[Master Code]+[8]Pressing [8] while in the User Function Command mode willsound the bell/siren, the keypad sounder and turn on a

Page 5 - SPECIFICATIONS

9PROGRAMMING GUIDEIntroductionThe PC1500 is fully programmable from the keypad and usesan EEPROM memory which can be reprogrammed thousandsof times. T

Page 6 - INSTALLATION

10Binary Data DisplayZone lights 1 through 4 are used to display the value, in binaryformat, of the data as shown in the table below.Hex Data Entry*Va

Page 7 - Telephone Line Wiring

11PROGRAMMING SECTIONS[00] Binary ProgrammingThis section is normally used upon instruction from factorytechnical personnel for specialized programmin

Page 8 - Living RoomKitchen

12[07] Closing (Arming) Reporting CodesPartial Closing Reporting CodeReporting codes 1 to 6 are used to identify closings foraccess codes 1 to 6. If

Page 9 - KEYPAD FUNCTIONS

13[2] Interior Zone is normally used with interior motiondetectors and has the standard Exit Delay time. The zonealso has the standard Entry Delay ti

Page 10 - User Programming Command

14[13] 2nd System Option CodeUse the same method of programming as Section [12].ZONELIGHT[1] • ON = Call 1st phone number onlyOFF = Call 1st phone num

Page 11 - User Function Commands

15[18] Auxiliary Delay ZoneEntry / Exit TimesThis section requires two 3-digit entries to establish theAuxiliary Entry and Exit Delay times. Do not p

Page 12

This manual is for the PC1500 software version 4.1INDUSTRY CANADA NOTICENOTICE: The Industry Canada label identifies certified equipment. Thiscertific

Page 13 - PROGRAMMING GUIDE

162. The zone alarm reporting codes must all be single digitnumerical codes with no extended 2nd round being sent(i.e. Zone 1 = 10, Zone 2 = 20... Zo

Page 14 - Binary Data Display

17[26] Downloading Telephone NumberThis telephone number is used by the panel to call thedownloading computer when a request to call is make byenterin

Page 15 - PROGRAMMING SECTIONS

18When the urgency option is selected for the audibile ExitDelay, the keypad will sound a pulsing tone during the ExitDelay. During the last 10 secon

Page 16 - Zone Definitions Digit #2

19FOR THE RECORDPC1500 Version 4.1Customer ___________________________________________________________________________________________________Address

Page 17 - [12] 1st System Option Code

20PROGRAMMING WORK SHEETSPC1500 Version 4.1NOTE: In sections [01] to [10], do not enter data into sections that are not used.[01] 1st Phone Number

Page 18 - [17] System Times

21PC1500 Version 4.1[07] Closing (Arming) Reporting Codes / Partial Closing Reporting Code Page 12Access Code 1Access Code 2Access Code 3Access C

Page 19 - Radionics Format

22PC1500 Version 4.1[10] Maintenance Alarms and Restorals Page 12For automatic test code reporting, time between reports (in days) must be specif

Page 20 - (PGM Terminal)

23PC1500 Version 4.1[13] 2nd System Option Code Page 14Default Zone Light ON Zone Light OFFON Zone Light 1 Call 1st phone only Backup to 2nd phon

Page 21 - Hardware

24PC1500 Version 4.1[16] Zone Bypass Mask Page 14If the zone light is ON, the zone can be bypassed using the [∗][1] command. If a zone is define

Page 22 - [36] Keypad Lockout Control

25PC1500 Version 4.1[21] New Master Code Page 15Default1234[22] 2nd Master Code Page 15The 2nd Master Code can be erased by entering [∗1111].

Page 23 - FOR THE RECORD

iTABLE OF CONTENTSFEATURES 1SPECIFICATIONS 1INSTALLATION 2Mounting the Panel ...

Page 24 - PROGRAMMING WORK SHEETS

26PC1500 Version 4.1[24] Programmable Output Options (PGM Terminal) Page 16Enter 2 digits from “01” to “0C” only.Default0 4 Programmable Output [

Page 25 - PC1500 Version 4.1

27PC1500 Version 4.1[28] Panel Identification Code Page 17Default1501This code confirms the panel’s identity to the downloading computer.[29] For

Page 26 - [11] Zone Definitions

28PC1500 Version 4.1[34] 6th System Option Code Page 17Default Zone Light ON Zone Light OFFOFF Zone Light 1 Audible Exit Delay with Urgency Stand

Page 27

29HOOKUP DIAGRAM+Battery ChargeCurrent is360 mA MaxPin 1Pin 116VAC40 VA min.12 Volt 4 AhGel-CellBATT5AmpAUX1AmpBELL5AmpEEPROMReset50 to 60Hz ACLOAD300

Page 28 - [20] New Installer’s Code

30LIMITED WARRANTYDigital Security Controls Ltd. warrants the original purchaser that for a period of twelve months from the date of purchase, the pro

Page 29 - [23] Communication Formats

31WARNING Please Read CarefullyNote to InstallersThis warning contains vital information. As the only individual in contact with system users, it is y

Page 30 - [27] Downloading Access Code

© 1999 Digital Security Controls Ltd.1645 Flint Road, Downsview, Ontario, Canada M3J 2J6www.dscgrp.comPrinted in Canada 29004755 R0011-800-387-363

Page 31

iiPROGRAMMING SECTIONS 11[00] Binary Programming ...

Page 32 - [34] 6th System Option Code

1FEATURESKeypad ProgrammableThe PC1500 is complete with a default program so that it isoperational with a minimum of programming. The controlpanel is

Page 33 - 360 mA Max

2INSTALLATIONMounting the PanelSelect a dry location close to an unswitched AC source andclose to the telephone line connection. Remove the printedcir

Page 34 - LIMITED WARRANTY

3Fire Zone WiringAny one of the 6 zones may be programmed as a Fire Zone.See Programming Guide Section [11].Smoke detectors should be the latching typ

Page 35 - WARNING Please Read Carefully

4GUIDELINES FOR LOCATING SMOKE DETECTORSExperience has shown that all hostile fires in family livingunits generate smoke to a greater or lesser extent

Page 36 - 1-800-387-3630

5KEYPAD FUNCTIONSIntroductionThe PC1500RK remote keypad provides complete informationand control of the PC1500 control panel. The panel can be fullypr

Comments to this Manuals

No comments