PC1500 Version 4.1
[16] Zone Bypass Mask
Page 14
If the zone light is ON, the zone can be bypassed using the [
][1] command. If a zone is defined as a fire zone,
it cannot be bypassed.
Default
ON Zone Light 1
ON Zone Light 2
ON Zone Light 3
ON Zone Light 4
ON Zone Light 5
ON Zone Light 6
[17] System Times
Page 14
Default
0 3 0 Entry Delay (seconds)
1 2 0 Exit Delay (seconds)
0 0 4 Bell Cut-off (minutes)
0 3 0 AC fail transmission delay (minutes)
0 5 0 Slow zone response time ( × 10 ms)
0 3 0 Test transmission cycle or auto download cycle time (days)
Valid entries are 001 to 255; do not enter 000.
[18] Auxiliary Delay Zone Entry/Exit Times
Page 15
Default
0 4 5 Entry Time (seconds)
1 2 0 Exit Time (seconds)
Valid entries are 001 to 255.
[19] System Clock Times
Page 15
Default
9 9 9 9 Automatic Arming (time of day)
9 9 9 9 Test transmission or auto download (time of day)
Enter 4 digits - 00 to 23 hours; 00 to 59 minutes. If not used, leave at default setting 9999.
[20] New Installer’s Code
Page 15
For Sections [20], [21] and [22]: Enter 4 digits from 0 to 9. Do not enter [
] or [#].
Default
1500