PROGRAMMING GUIDE
Introduction
The PC1500 is fully programmable from the keypad and uses
an EEPROM memory which can be reprogrammed thousands
of times. The EEPROM memory will not lose the program data
even on total loss of power. The essential information which
defines the operation of the control panel is stored in a
section of the EEPROM memory which is accessible using
the Installers Programming code or via downloading. If the
Installers code is forgotten, the EEPROM may be reset to the
factory default code. See Section [30], Reset to Factory
Default.
Programming
With the panel in the disarmed mode, enter [
][8][1500].
The panel can only be programmed while it is in the disarmed
mode. The default installers code is 1500; the installers
code can be changed. See Section [20], New Installers
Code.
Once the installers command is entered, the Armed light
will come ON steadily and the Memory, Bypass and
Trouble lights will flash. This indicates that the panel is
ready for programming. NOTE: If no key entry is made for
2 minutes, the panel will return to the Ready mode and the
complete installers command will have to be entered before
programming can be resumed.
With the Armed light ON steadily, enter 2 digits for the
section you wish to program. The sections for the PC1500
panel range from [01] to [36], and each section can be
programmed independently. Section [00] is reserved for
binary programming which is normally done on instruction
from factory technical personnel.
Once the 2 digits for the section you wish to program are
entered, the Armed light will go OFF, the Ready light will
go ON steadily, and the keypad sounder will beep 3 times.
The keypad is now ready to accept data for the selected
section.
Most sections contain groups of 2-digit entries and the
keypad buzzer will beep twice after each 2-digit group is
entered.
When the section is first entered, the first 4 zone lights will
indicate, in a binary format, the value of the first digit in that
section (refer to Binary Data Display on the next page). If
you wish to change that digit, simply enter the new digit from
the keypad. If you wish to keep that digit unchanged, you can
enter the same number or skip the digit by pressing the [F]
key. Once the first digit has been entered or skipped, the 4
zone lights will display the value of the second digit. After
each digit is entered or skipped, the zone lights show the
value of the next digit in the binary format.
When the required data for the section being programmed is
completely entered, the keypad sounder will beep several
times and the Armed light will come ON to indicate that the
expected data has been entered.
At this point, you will still be in the program mode and need
only enter the section number for the next section you wish
to program.
It is not necessary to program all 2-digit pairs in any given
section. A section can be entered and selectively programmed
by going only to the digit(s) you wish to change and then
pressing [#] to return to the programming mode where you
can then enter another section number for programming. For
2-digit pairs, both digits must be programmed before pressing
the [#] key. Only the data entered before pressing the [#] key
will be changed in the EEPROM.
Program Data Review
Enter the section you wish to program by entering the 2-
digit section number.
The first 4 zone LEDs will represent the value, in binary
format, of the first digit in that section.
Each press of the [F] key will advance the display to the
next digit.
At the end of the section, the keypad will beep several
times and then return to the program mode so that
another section can be selected for review or
programming.
NOTE: Only Sections [01] through [11], [15], and [17]
through [28] can be reviewed using the method described
above.
Sections [12], [13], [14], [16], [31], [32], [34]
These sections use the zone lights to indicate which functions
are active and which number key to press to turn them ON
and OFF. When one of these sections is entered, zone lights
1 to 6 will display which functions are currently ON. Pressing
the key number corresponding to the zone light number will
alternately turn the function ON and OFF, and the zone light
will correspond to this. All functions can be turned OFF at
once by pressing [0]. When the correct selections have been
made, press [#] to save the selections in memory and return
to the program mode where another section can be selected.