Reporting Codes
43
Section # Reporting Code Code Sent When...
Dialer
Direction*
Automatic
Contact ID
Codes
SIA Auto Rep
Codes**
[344] Special Opening Opening (disarming) using one of the following methods: key-
switch, maintenance code, DLS software, wireless key
O/C (4) AA OP-00
[345]-[346] Battery Trouble/Rest. PC5020 battery is low/battery restored MA/R (3) A2 YT-00/YR-00
[345]-[346] AC Line Trouble/Rest. AC power to control panel is disconnected or interrupted/AC
power restored (Both codes follow AC Failure Comm. Delay.)
MA/R (3) A1 AT-00/AR-00
[345]-[346] Bell Circuit Trouble/Rest. Open or short circuit detected across bell terminals/bell circuit
restored
MA/R (3) 21 YA-99/YH-99
[345]-[346] Fire Trouble/Rest. Trouble occurs/restores on a fire zone MA/R (3) 73 FT-00/FJ-00
[345]-[346] Auxiliary Power Trouble/Rest. Aux voltage supply trouble/restoral MA/R (3) AA YP-00/YQ-00
[345] TLM Failure Telephone line monitoring trouble (sent via LINKS1000. Do not
program if LINKS1000 not used)
MA/R (3) 51 LT-00
[346] TLM Restore Telephone line restored MA/R (3) 51 LR-00
[345]-[346] Gen System Trouble/Rest. “Service Required” trouble occurs (view troubles using [*][2])/
trouble restored
MA/R (3) AA YX-00/YZ-00
[345]-[346] Gen System Supervisory Trou-
ble/Rest.
Control panel loses/restores communications with module(s)
connected to the Keybus
MA/R (3) 33 ET-00/ER-00
[347] Phone# 1 or 2 FTC Restoral Control panel has restored communications to central station
on Phone# 1 or 2 (after FTC)
MA/R (3) 54 YK-00
[347] Event Buffer is 75% Full Event buffer is almost full since last upload MA/R (6) 23 JL-00
[347] DLS Lead In Downloading session start MA/R (4) 11 RB-00
[347] DLS Lead Out Downloading session complete MA/R (4) 12 RS-00
[347] Zone Fault/Rest. One or more zones have faults/restored MA/R (3) 72 UT-ZZ/UJ-ZZ
[347] Delinquency Programmed amount of time (days or hours) for delinquency
has expired without zone activity, or without system being
armed
MA/R (4) 54*** CD-00
[347] Wireless Device Low Battery
Trouble/Rest.
Wireless zones, panic pendants, handheld keypads, wireless
keys have low battery/all low batteries restored
MA/R (3) 84 XT-00/XR-00
XT-ZZ/XR-ZZ****
[347] Installer Lead In Installer’s mode has been entered MA/R (6)27 LB-00
[347] Installer Lead Out Installers mode has been exited MA/R (6)28 LS-00
[348] Walk Test End End of test T (6) A7 TS-00
[348] Walk Test Begin Beginning of test T (6) A7 TE-00
[348] Periodic Test with Trouble Periodic system test transmission with trouble T (6) A8 RP-01
[348] Periodic Test Periodic system test transmission T (6) A2 RP-00
[348] System Test [*][6] bell/communications test T (6) A1 RX-00
[348] LINKS1000 Test LINKS1000 test transmission T (6) A3 TX-00
[349] PC5700 Ground Fault Trouble/
Restore
Ground/Fault/Trouble occurs on the PC5700 MA/R (3) 1A US-00
[349] PC5700 TLM Line 1 Trouble/
Restore
TLM Trouble /Restore occurs on the PC5700 MA/R (3) 51 LT-XX
[349] PC5700 TLM Line 2 Trouble/
Restore
TLM Trouble /Restore occurs on the PC5700 MA/R (3) 52 LR-XX
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
** UU = user number (user01-42); ZZ = zone number (01-64)
*** Use the “Fail to close” event code [(4)54] to report closing or activity delinquency. Ensure the central station is aware that this code is used.
**** Zones are identified, panic pendants, wireless keys, and handheld keypads are not.