Programming Sections: 5.3 Basic Programming PWS Sect 3
25
Option Definition On/Off Description
2 Verbal Door Chime ON Verbal Door Chime is Enabled. The system will verbally annunciate the zone (or programmed
label) when it is violated if Door Chime is programmed.
This feature is available when ESCORT5580 v3.00, and the PC5936 v1.00 are used. This feature
enables the Door Chime to verbally annunciate the Zone that has been violated instead of a series of
beeps, If the Verbal Chime Feature is enabled, whenever a zone with the Chime attribute enabled is
violated, a series of beeps will sound and the system will verbally prompt “Zone X”. When the zone
is restored, the system will sound a series of beeps. For example, if label is programmed for the above
Zone, the system will verbally annunciate (after the beeps) “South Bedroom Window”. See associ-
ated Installation Manuals
NOTE: Only beeps are annunciated on a zone restore.
OFF Verbal Door Chime is Disabled. The system will only annunciate a series of beeps whenever a zone
programmed for Chime is either violated or restored. This option is defaulted OFF.
3 Verbal Alarm ON Verbal Alarm is Enabled. The system will verbally annunciate audible zone alarms via their zone
number (or programmed label) in conjunction with the Bell Outputs.
This feature is available when the ESCORT5580 v3.00 and PC5936 v1.00) are used. This feature
enables verbal annunciation of alarm conditions on the system. When an audible non-fire zone goes
into alarm with this feature is enabled, the PC5020 will sound the alarm condition via the Bell Out-
puts, but every 15 seconds (as programmed in the Alarm Tone Period – Section [178]) it will silence
the bell outputs and the PC5936 speakers will verbally annunciate the alarm condition “Alarm Zone
4” or, if the label is programmed, “Alarm South Bedroom Window”
When the zone is in alarm, the software automatically inserts the word “Alarm” in front of the
appropriate zone label.
When an audible fire zone goes into alarm, the system automatically inserts the words “Fire” and
“Alarm” in front of the appropriate zone label (“Fire Alarm Zone 4” or “Fire Alarm South Bed-
room Smoke”).
If there are multiple alarms, the system will annunciate the first and latest zone that has gone into
alarm.
NOTE: Fire annunciation always overrides any Burglary Zone alarm annunciation. Ver-
bal Alarm will cease with the Siren at Bell Time Out.
OFF Verbal Alarm is Disabled. The system will only annunciate via the Bell Outputs during an audible
alarm condition. This option is defaulted OFF.
4 Waterflow Silence
Inhibit
ON Water-flow Silence Enabled. An Instant or Delayed 24Hr Water-flow alarm can not be silenced by
any means (including Bell Time Out) until all Water-flow zones on the system are restored.
OFF Water-flow Silence Disabled. Alarms can be silenced whether a Water-flow zone is open on the
system or not. This Option is OFF at default.
5 Keypad Buzzer
Alarm
ON Keypad Buzzer Follows Bell Enabled. The keypad buzzers will follow the selected partitions bell
activity.
OFF Keypad Buzzer Follows Bell Disabled. The keypad buzzer will not follow all bell activity. Only
alarms designated to activate the keypad buzzer will do so. This option is OFF at default.
6 Cross Zoning /
Police Zone Select
ON Cross Zoning is Enabled. The panel will use the Cross Zone Attribute for Burglary Verification.
This feature requires two or more trips on a zone(s) specified as “cross zones” within a specified time
before starting an alarm sequence. See Section [101],Option 9, Pg 33.
When a zone with the Cross Zone Attribute Enabled is violated, nothing occurs on the local premises
(except Entry Delay, if applicable) and the Cross Zone Timer commences. If another Zone with the
Cross Zone attribute enabled is violated before the timer expires, the panel will transmit the first
alarm signal, a Cross Zone event , followed by the second zone alarm, and begins the appropriate
local alarm sequence. If no other zones are violated before the timer the expires, no alarm sequence
occurs and an Alarm Not Verified event is logged. If the Double Hit Feature is enabled (Section [017],
Option 4), the panel will react on two violations of the same zone during the Cross Zone Timer (Sec-
tion [176]) for starting an alarm sequence.
This option is dependent on the programming of the Burglary Verification Options (Section [018],
Option 6). It is not enabled if Police Code is enabled.
This option will not function on zones that do not log alarm events (e.g. While disarmed, Day Zone,
Instant zone, etc.)
NOTE:The Cross Zone/Police Code Timer is in Seconds for Cross Zoning and in Minutes for Police
Code.
NOTE:No fire zones types should use the Cross Zone Attribute.
OFF Police Code is Enabled. The panel will use the Police Code feature for Burglary Verification. This
option is OFF at default.
7 Exit Delay Restart ON One Time Exit Delay Restart on Delay zone re-entry Enabled. If a Delay zone is violated and
restored during the Exit Delay, it is considered an exit. If a delay zone is violated again it is considered
a re-entry. With this option enabled the panel will restart the exit delay. Further violations and
restores of delay zones will not restart the exit delay. NOTE: Option is ON by default.
OFF One Time Exit Delay Restart on Delay zone re-entry Disabled. Delay zone violations and
restores will not restart the exit delay.
NOTE: The exit delay can only be restarted once. This includes restarts from Away func-
tion keys.
8 AC Trouble Beeps ON AC Trouble Beeps Enabled. When an AC trouble occurs on the panel, all keypads will sound an
audible trouble indication (2 beeps every 10 seconds)
OFF AC Trouble Beeps Disabled. AC troubles will remain silent. This option is OFF at default.