14
select Partition 1 (see section 4.4 Global and Partition Keypad Opera-
tion on page 15).
[02] - Select Partition 2
Provides an easy way to select Partition 2. This is the same as press-
ing and holding the [#] key then pressing and holding the [2] key to
select Partition 2 (see section 4.4 Global and Partition Keypad Opera-
tion on page 15).
[03] - Stay Arm
Same as described in Function Keys - Section 3.5.
[04] - Away Arm
Same as described in Function Keys - Section 3.5.
[05] - [*]+[9] No-Entry Delay Arm
After this function key is pressed the user must enter a valid access
code. The Partition will arm and remove entry delay from the parti-
tion when the exit delay expires (see section [Q] [9] Arming Without
Entry Delay on page 13).
[06] - [*]+[4] Door Chime On/Off
This function key provides the user a simple method for turning the
Door Chime feature on and off (see section [Q] [4] Door Chime On/
Off on page 11).
[07] - [*]+[6]...[4] System Test
This function key provides the user with a simple method for testing
the system (see section [Q] [6] User Functions on page 12). A valid
Master Code is required to perform this command.
[08] - [*]+[1] Bypass Mode
This function key provides the user with a simple method for enter-
ing the Bypass Mode. If a access code is required it must be entered
before bypassing can be performed (see section [*][1] Zone Bypass-
ing on page 10).
[09] - [*]+[2] Trouble Display
This function key provides the user with a simple method for enter-
ing the Trouble Display Mode (see section [*][2] Trouble Display on
page 11).
[10] - [*]+[3] Alarm Memory
This function key provides the user with a simple method for enter-
ing the Alarm Memory Display Mode (see section [Q] [3] Alarm
Memory on page 11).
[11] - [*]+[5] Programming Access Codes
This function key provides the user with a simple method for pro-
gramming access codes. After this key is pressed a valid System Mas-
ter or Supervisor Code will have to be entered before the panel will
allow programming to be performed (see section [Q] [5] Program-
ming Access Codes on page 12).
[12] - [*]+[6] User Functions
This function key provides the user with a simple method for pro-
gramming User Functions. After this key is pressed a valid System
Master or Partition Master must be entered before the panel will
allow User Functions to be performed (see section [Q] [6] User Func-
tions on page 12).
[13] - [*]+[7]+[1] Command Output Option 1
This function key provides the user with a simple method for activating
a PGM Output programmed as Command Output Option 1 (See Sec-
tion 5.8 Programmable Output Programming PWS Sect 8). By
default, after this key is pressed a valid access code must be entered
(see section [Q] [7] Command Output Functions on page 13).
[14] - [*]+[7]+[2] Smoke Detector Reset
This function key provides the user with a simple method for activat-
ing a PGM output programmed as either option [03] Sensor Reset or
[20] Command Output option 2.
[15] - General Voice Prompt Help
This feature can only be programmed if both the Escort5580 and the
PC5936 Audio Matrix module are being used.
When the function key is pressed, the intercoms will perform a Help
page. The user must then press the Page/Answer button on any
intercom station to begin the help session with the Escort.
For more information, Refer to the PC5936 Installation Manual.
NOTE: While the voice prompt help is active, users will not be able
to disarm the system using Wireless Keys.
[16] - [*]+[0] Quick Exit
Same as described in Function Keys - Section 3.5.
[17] - [*]+[1] Reactivate Stay/Away Zones
This function key provides the user with a simple method for adding
Stay/Away zones back into the system (see section [*][1] Zone
Bypassing on page 10).
[18] Identified Voice Prompt Help
This feature can only be programmed if the Escort5580 and the
PC5936 Audio Matrix module are being used.
When the function key is pressed, the Escort will begin a help session
from the intercom station programmed as closest to the keypad. In
order for this option to function, you must program PC5936 Section
[802], subsection [14] “Keypad Port Assignments.” For more infor-
mation, Refer to the PC5936 Installation Manuals.
NOTE: This function key cannot be programmed for PC55XXZ LED
keypads with software version 1.0.
NOTE: While the voice prompt help is active, users will not be able
to disarm the system using Wireless Keys.
[19] - [*]+[7]+[3] Command Output 3
[21] - [*]+[7]+[4] Command Output 4
Function Keys [19] and [21] provide the user with a simple method of
activating an output programmed as Command Output Option 3 or 4.
[22] - Active Camera Monitor Selection
This function key is for use with the PC5108L Downlook Interface/
Camera Monitor Module. For instructions on the function key use,
see the PC5108L Installation Manual.
[23] - Bypass Recall
Pressing this function key will recall the last group of bypassed zones.
The function key will follow the Code Required for Bypass option. If
the option is enabled, a valid access code with the Bypass attribute
enabled must be entered after the function key is pressed. For instruc-
tions on zone bypassing, see the Power864 Instruction Manual.
[24] - Recall Bypass Group
This function key will recall zones in the Bypass Group for the parti-
tion. This group is programmed by the user in the [*][1] Bypass
menu. The function key will follow the Code Required for Bypass
option. If the option is enabled, a valid access code with the Bypass
attribute enabled must be entered after the function key is pressed.
For instructions on zone bypassing and programming Bypass Groups,
see the Power864 Instruction Manual.
[25]-[26] - For Future Use
[27] - Select Partition 3
[28] - Select Partition 4
[29] - Select Partition 5
[30] - Select Partition 6
[31] - Select Partition 7
[32] - Select Partition 8
These keys provide users with an easy way to select one of the above
partitions. For example, this is the same as pressing and holding the
[#] key, then pressing and holding the [3] key to select Partition 3
(see section 4.4 Global and Partition Keypad Operation on page 15).