1
System Introduction
S E C T I O N 1
1.1 Specifications
Control Panel Specifications
Flexible Zone Configuration:
8 Fully Programmable Zones
38 Access Codes: 32 User, 1 System Master, 2 Partition Master, 2 Duress and 1 maintenance
Expandable to 32 Zones
Keypads with zone inputs available (PC/KP5508Z, PC/KP5516Z, PC/KP5532Z, LCD/KPL5500Z)
Hardwired expansion available using the PC5108 Eight Zone Expansion Module
Wireless expansion available using the PC5132 Wireless Zone Expansion Module (up to 32 wireless
zones, 900MHz, True Spread Spectrum Technology, Fully Supervised)
Normally Closed, Single EOL, or Double EOL zone supervision
2-Wire Smoke Input (via PGM2 input)
27 Zone Types, 8 Programmable Zone Options
2 Partitions
Audible Alarm Output:
Supervised Bell Output (current limited at 3 amps), 12 V
DC
Steady or Pulsed Output
EEPROM Memory:
Will not lose programming or system status on complete AC and Battery failure
Programmable Outputs:
Up to 14 Programmable Voltage Outputs, 23 programmable options
One High Current (300 mA) PGM output with 2 wire smoke detector capability on main panel
Maximum Loop Current is 1.5 mA when the 2-wire smoke detector configuration is used
One Low Current (50 mA) PGM output on main panel
Eight Additional Low Current (50 mA) PGM outputs available using the PC5208 module
Four High Current (1 Amp) PGM outputs Available Using the PC5204 module
1 PC5204 Output Fully Supervised for Siren Output
Powerful 1.5 Amp Regulated Power Supply:
500 mA Auxiliary Supply, 12 V
DC
Positive Temperature Coefficient (PTC) components replace fuses
Supervision for loss of AC Power, Low Battery
Internal Clock Locked to AC Power Frequency
Power Requirements:
Transformer = 16.5 VAC, 40VA
Battery = 12 volt 4 Ah minimum rechargeable sealed lead acid
Remote Keypad Specifications:
8 Different Keypads Available:
- PC5508(Z)/KP5508(Z) 8 Zone LED Keypad - PC5532(Z)/KP5532(Z) 32 Zone LED Keypad
- PC5516(Z)/KP5516(Z) 16 Zone LED Keypad - LCD5500(Z)/KPL5500(Z) Alphanumeric Keypad
Each Keypad has 5 Fully Programmable Function Keys Connect up to 8 Keypads
Four Wire (Quad) Connection to Keybus Built in Piezoelectric Buzzer
Digital Communicator Specifications:
Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging
3 Programmable Phone Numbers 2 Account numbers
Supports LINKS1000 Cellular Communication DTMF and Pulse Dialing
DPDT Line Seizure Anti-jam Feature
Split Reporting of Selected Transmissions to Each Telephone Number
System Supervision Features
The PC5010 continuously monitors a number of possible trouble conditions including:
AC Power Failure Trouble by Zone Fire Trouble
Telephone Line Trouble Low Battery Condition Bell Output Trouble
Loss of Internal Clock AUX Power Supply Fault Tamper by Zone
Failure to Communicate Module Fault (Supervisory or Tamper)
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - System Introduction

1System IntroductionS E C T I O N 11.1 SpecificationsControl Panel SpecificationsFlexible Zone Configuration:• 8 Fully Programmable Zones• 38 Access

Page 2 - 1.2 Additional Devices

G E T T I N G S T A R T E D102.8 Removing ModulesIf a module is no longer required on the system the panel must be told to no longer supervise the mo

Page 3

G E T T I N G S T A R T E D112.9.4 Fire Zone Wiring - 4 wire Smoke DetectorsAll zones defined as Fire (See Section 5.1 “Zone Definitions”) must be wi

Page 4 - 1.3 Out of the Box

G E T T I N G S T A R T E D122.10 Keypad ZonesKeypads with zone inputs can be connected to devices such as door contacts. This saves you fromrunning

Page 5 - Getting Started

Keypad CommandsS E C T I O N 313All keypads provide complete information and control of the alarm panel. The panel can be completely programmedvia an

Page 6 - 2.2 Terminal Descriptions

K E Y P A D C O M M A N D S143.3 Auto BypassWhen the system is armed and any zone or zone(s) on the system have been programmed as Stay/Awaythe panel

Page 7

K E Y P A D C O M M A N D S15A description of the various troubles are as follows:Trouble [1] - Service Required This light will be on if any of th

Page 8

K E Y P A D C O M M A N D S16[✱]+[4] Door Chime On/OffIf enabled the keypad will beep 5 times rapidly when a zone is tripped and restored. The panel

Page 9 - 2.7 Enable Supervision

K E Y P A D C O M M A N D S17How to erase Access Code:Select the code to be erased and press [✱].[✱]+[6] User FunctionsThis keypad command can be use

Page 10 - 2.9 Zone Wiring

K E Y P A D C O M M A N D S18[✱✱✱✱✱] [7] Command Output FunctionsThere are four output functions available to the user. Each function can be performe

Page 11 - G E T T I N G S T A R T E D

K E Y P A D C O M M A N D S19“Chime” - Door Chime On/OffPressing the key will toggle the Door Chime feature ON or OFF. One solid beep means the featu

Page 12 - 2.10 Keypad Zones

S Y S T E M I N T R O D U C T I O N2False Alarm Prevention Features• Audible Exit Delay •Audible Exit Fault •Urgency on Entry Delay• Quick Exit •Swin

Page 13 - Keypad Commands

K E Y P A D C O M M A N D S20[14] - [✱]+[7]+[2] Smoke Detector ResetThis function key provides the user with a simple method for activating a PGM out

Page 14 - 3.4 [✱] Commands

How to ProgramS E C T I O N 421The following section of the manual describes how to enter Installer Programming and how to program the varioussection

Page 15 - K E Y P A D C O M M A N D S

H O W T O P R O G R A M22If you are using a pulse format, a decimal zero [0] does not transmit. Programming a zero [0] tells thepanel not to send an

Page 16

Program Descriptions23S E C T I O N 5The following section explains all the programmable features including how the feature operates, options thatper

Page 17

P R O G R A M D E S C R I P T I O N S24[09] 24 Hour Supervisory Zone If this zone is violated, whether armed or disarmed, the panel will report toth

Page 18 - 3.5 Function Keys

P R O G R A M D E S C R I P T I O N S25Swinger Shutdown Enable (Shall not be enabled on UL Listed systems) Determines if the panel willshut down th

Page 19

P R O G R A M D E S C R I P T I O N S265.5 Communicator - Account NumbersThere are two Partition Identifier Codes (or Account Numbers) programmable,

Page 20 - ] Commands, [

P R O G R A M D E S C R I P T I O N S27If the SIA Sends Automatic Reporting Codes option is disabled the panel will operate as follows:1.If the repor

Page 21 - How to Program

P R O G R A M D E S C R I P T I O N S28A Partial Closing Reporting Code will be transmitted if a Partition is armed with zones manuallybypassed. The

Page 22 - 4.5 Viewing Programming

P R O G R A M D E S C R I P T I O N S29The Auxiliary Power Supply Trouble Alarm Reporting Code will be transmitted if the AUX output isshorted. The A

Page 23 - Program Descriptions

S Y S T E M I N T R O D U C T I O N3WLS907 Wireless Slimline Universal TransmitterThe wireless Slimline Universal Transmitter can be used with the PC

Page 24 - 5.2 Zone Attributes

P R O G R A M D E S C R I P T I O N S30Reporting Codes ... Sect

Page 25 - 5.3 Communicator - Dialing

P R O G R A M D E S C R I P T I O N S31Keypads can be assigned to work on either partition or can be assigned for Global operation (SeeSection 2.6 “K

Page 26

P R O G R A M D E S C R I P T I O N S32[10] Latched System Event (Strobe Output) The output will activate when any of the selected systemevents (al

Page 27

P R O G R A M D E S C R I P T I O N S335.10.2 PGM Output AttributesIn addition to programming the output type, you must also program the PGM output a

Page 28

P R O G R A M D E S C R I P T I O N S34Bell Cut-off ... Section [005]Bell Circuit Trouble

Page 29

P R O G R A M D E S C R I P T I O N S35For commercial applications Bell Squawk on Entry Delay may be enabled. The panel will squawk thealarm output o

Page 30 - 5.8 Downloading

P R O G R A M D E S C R I P T I O N S365.19 Keypad BacklightingThe keys of all the keypads can be backlit to provide easy viewing in dim lighting con

Page 31 - 5.10 PGM Outputs

P R O G R A M D E S C R I P T I O N S375.24 Loop ResponseThe normal loop response time for all zones is 500 milliseconds. The panel will not consider

Page 32

P R O G R A M D E S C R I P T I O N S38Please refer to the LINKS1000 installation Manual for more information and connection diagrams.LINKS Preamble

Page 33 - 5.12 Siren

P R O G R A M D E S C R I P T I O N S395.29 On-Site PrinterThe panel, with the addition of the PC5400 printer module, will print all events as they o

Page 34 - 5.15 Entry/Exit Delay Options

S Y S T E M I N T R O D U C T I O N4Three additional devices are available (These devices are not UL Listed):PC5921 Intercom Audio Station (This devi

Page 35 - 5.18 Transmission Delay

P R O G R A M D E S C R I P T I O N S405.32 Installer LockoutIf Installer Lockout is selected a hardware default cannot be performed. If a software d

Page 36 - 5.23 Keypad Blanking

Contact IDThe Partition ID Codes must be 4 digits. All reporting codes must be 2 digits.The following is a list of Contact ID reporting codes. The fir

Page 37 - 5.25 Keypad Tampers

42SIA FormatLevel 2 (Hardcoded)The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communica-tion

Page 38 - 5.28 Escort5580 Module

LIMITED WARRANTYDigital Security Controls Ltd. warrants the original purchaser that for a period of twelvemonths from the date of purchase, the produc

Page 39 - 5.31 Default (Factory)

© 1997 Digital Security Controls Ltd.1645 Flint Road, Downsview, Ontario, Canada M3J 2J6Tel. (416) 665-8460 • Fax (416) 665-7498 • Tech. Line 1-80

Page 40 - 5.33 Walk Test (Installer)

PC5O1OVersion 2.ODLS-1 version 6.4 or laterWARNING This manual contains information on limitations regardingproduct use and function and information

Page 41 - Contact ID

FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use th

Page 42 - SIA Format

Table of ContentsiPC5010 Control Panel Hookup Diagram ... iiSection 1 - System Introduction1.1 Specifications ...

Page 43 - WARNING Please Read Carefully

Hookup DiagramP C 5 0 1 0 C O N T R O L P A N E Lii

Page 44

Getting StartedS E C T I O N 25The following sections provide a complete description of how to wire and configure devices and zones.2.1 Installation

Page 45 - Installation

G E T T I N G S T A R T E D62.2 Terminal DescriptionsAC Terminals - ACThe panel requires a 16.5 volt, 40 VA transformer. Connect the transformer to a

Page 46

G E T T I N G S T A R T E D7Ensure the plugs and jacks meet the dimension, tolerance and metallic plating requirements of 47C.F.R. Part 68, SubPart F

Page 47

G E T T I N G S T A R T E D8Other DevicesRead the manufacturer’s literature carefully to determine the maximum current requirement (duringactivation

Page 48 - Hookup Diagram

G E T T I N G S T A R T E D92.6 Keypad AssignmentThere are 8 available slots for keypads. LED keypads by default are always assigned to slot 1 while