3rd System Option Code
Refer to Section
[12]
for programming information.
LIGHT
111
ON =
Access code required for bypass
l OFF =
Access code not required for bypass
PI
ON =
Enable
[*][4]
downloading call feature
l OFF
=
Disable
[*][4]
call feature’
131
ON = Periodic
downloading2
l OFF = Periodic test transmission
141
ON =
[*][4]
requires a Access Code
l OFF
=
[*][4]
does not require Access Code
[RI
l ON
=
[*][#I
Panic Alarm has keypad-audible feedback
OFF =
[*][#I
Panic Alarm does not have keypad-audible feedback
PI
ON
=
Partial closings identified
3
. OFF =
Partial closings not identified
[R] = “Ready” light; [A] = “Armed” light
l Factory default settings
l
[*][4]
allows downloading to be initiated from the control panel
2
The panel can be programmed to periodically call the downloading computer. The cycle time in days for
the call is set in Section
[19].
The automatic call to the downloading computer can be used to update the
panel program and/or to upload status information from the panel.
3
If partial closings to be identified, alarm codes for bypassed zones will be transmitted.
[15]
Communication Variables
Enter a
2-digit
number in this Section. This number defines the number of attempts the communicator will make
to transmit alarm and
restoral
reports
for a zone before the communicator shuts down for that zone. The number
of attempts is for the period defined in Section
[12],
1st System Option Code, Light 2. The number of
communication attempts may be programmed from [00] to
[99],
where ‘00’ means the communicator will never
shut down. Note that the fire zone cannot be shut down; it always transmits.
[16l
Zone Bypass Mask
Refer to Section
[12]
for programming information. If a zone light is ON, that zone can be bypassed; if a zone light
is OFF, that zone cannot be bypassed using the
[*][l]
command. Note that the fire zone cannot be bypassed.
[I71
System limes
Six system times are programmed in Section
[17];
each time requires a 2-digit number. Do not press the
[#]
Key during data entry.
PI
PI
[31
[41
Entry Delay
(01 to 99 seconds) Location [I] holds the standard Entry Delay time. The default setting is
30 seconds; refer to Section
[l
I]
for information on Zone Definitions.
Exit Delay
(01 to 99 seconds) Location
[2]
holds the standard Exit Delay time. The default setting is 45
seconds; refer to Section
[l
l]
for information on Zone Definitions.
Siren Cut-Off
(01 to 99 minutes) Location
[3]
determines how long the siren will sound when an alarm is
generated. The default setting is 4 minutes.
AC Failure Transmission Delay (01
to 99 minutes) Location
[4]
determines the length of time before the
communicator will transmit an AC failure report. The default setting is 30 minutes.
19