Page view 16
3/f
format
-
Non-extencfed
reporting
Requires:
l 3-digit account code in sections
[02]
or
1041.
For example, enter 1230 for account code 123
l Format Code [0],
[l],
[2],
[3],
[4]
depending on receiver type in section
[23].
l
Single line digit Alarm Reporting Code Section
[05].
For example, enter
[30]
for
single digit code 3 (0 = no pulses)
TRANSMISSION SENT: 123 3
4/2
Format
-
Non-extended reporting
Requires:
l 4-digit account code in sections
[02]
or
[04].
For example, enter 1230 for account code 123
l Format Code [0],
[l],
[23,
[3],
[4]
depending on receiver type in section
[23].
l
2-digit
Alarm Reporting Code in section
[05].
For example, enter
[31]
for 2-digit code 31
TRANSMISSION SENT: 1234 31
3/l
Format
-
Extended reporting
Requires:
l
3-digit
Account Code in section
[02]
or
[04].
For example, enter 1230 for code 123
0
Format Code
[8],
[9],
[A],
[B],
[C] depending on receiver type in section
[23]
l
2-digit
Alarm Reporting Code in section
[05].
For example, enter
[31]
for 2-digit code 31
TRANSMISSION SENT: 1
st ROUND
123 3
2nd ROUND 333 1
If a transmission is not needed for a particular reporting code, enter [00] or [FF] to disable that reporting code.
[06]
Zone
Restoral
Reporting Codes
Zone
Restoral
Codes are transmitted when zones 1 through 6 are restored from an alarm condition. Refer to
Section
[05]
for programming instructions.
1071
Closing
(Arming) Reporting Codes
/
Partial
Closing
Reporting Code
Closing Reporting Codes are transmitted to
identify
arming of the system
by
Access Codes 1 through 6.
If Partial
Closing is identified in Section
[14],
the alarm codes for manually bypassed zones will be transmitted when the
system is armed with one or more zones bypassed. Refer to Section
[05]
for programming instructions. The
Closing Reporting Codes may be programmed as follows:
WI
WI
P31
K41
WI
WI
The first digit, HEX ‘C’, represents “closing”, and the second digit represents the Access Code which was used
to arm the system. Note that any number or HEX digit may be used for the first digit; check with the intended
monitoring station to determine their reporting code preferences.
The Closing Code transmission takes place after the Exit Delay. If the system is
armed
and then disarmed before
the Exit Delay expires, no closing transmission will take place.
The partial closing code, if used, is transmitted with the regular closing code to identify a partial closing.
When the system has been armed using the
[*][O]
Quick-Arm command or the Auto-Arm feature,
Access Code 1 will be transmitted.