DSC PC1150 Installation Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 38
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
Radionics Format
For conventional Radionics
3/l
format, the communications mode should be set on either Radionics rounds [B]
or Radionics parity
[Cl.
The extended version of the Radionics format is normally used. Use the following
guidelines to configure the PC1 150 for Radionics format:
The customer account code must be only 3 digits with a zero making up the 4th digit.
For example, enter
1230 to program the account code as 123.
The zone alarm reporting codes must all be single digit numeric codes with no extended second round being
sent; for example, Zone 1 =
IO,
Zone 2 = 20, and so on. Zero as the second digit prevents the control panel
from sending an extended round.
All non-alarm reporting codes must be set up to send an extended second round. The first digit of the reporting
code is used to identify the event, while the second or extended digit is used to associate the event with a
particular item. For example, a reporting code of E3 means “restore zone 3”; E = restore, 3 = zone 3.
The following is a list of first digit identifiers that should be used with the Radionics format:
l Restorals “E”. For example, E3 = “restore zone 3”
l Openings “B”. For example,
82
= opening by user 2
.Closings “C”. For example, C4 = closing by user 4
*Troubles
‘IF”.
For example,
F5
= trouble from source 5
l Miscellaneous “D”. For example, Dl = partial closing
[24]
Programmable Output Options
/
PGM Terminal
The PGM output can be programmed to operate in response to various panel operations. The output pulse
connects the PGM terminal to the negative power rail.
WI
PI
(031
(041
WI
WI
WI
Not Used
Utility Output, no Access Code
Whenactivated byenteringthe [*][7]command, thePGMoutputwill golowfor5secondsandthekeypad
buzzer will sound.
Utility Output, any Access Code
The same as
[02],
except the command is
[*][7]
[any valid Access Code].
5-Second
Reset Pulse
When this option is selected, the PGM output is normally low. That is, it is the reverse of all other options
which are normally high and go low when activated. To activate this output, enter the
[$][7]
command.
The PGM terminal will go high (open circuit), and thus remove power from the devices connected. The
keypad buzzer will sound for the
Ssecond
period.
Courtesy Pulse
This
option
provides an output which follows the
Entry
and Exit Delays.
It can be used to turn on a
courtesy
light near the exit door for the duration of the Entry or Exit Delays.
Keypad Buzzer Follow Mode
The PGM output will go low as long as the keypad buzzer is ON for 24 Hour Buzzer Zone, Door Chime,
Entry Delay and Auto-Arm Alert.
System Status (Armed / Disarmed)
The PGM output switches to and remains at ground as long as the panel is armed. The output goes high
(open) when the panel is disarmed.
22
Page view 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 37 38

Comments to this Manuals

No comments