2. Use the keys to scroll to Buzzer Control.
3. There are 21 different levels, use the keys to scroll to the desired level.
Viewing the Event Buffer
The event buffer will show you a list of the last 128 events that have occurred on your system.
1. Press [Master Code].
2. To select Event Buffer viewing, press .
3. The keypad will display the event number and the time and date. Press to switch between
this information and the event details.
4. Use the keys to scroll through the events in the buffer.
5. To exit event buffer viewing, press .
Testing Your System
NOTE: Inform your Monitoring Station when you begin and end System Testing.
All smoke detectors in this installation must be tested by your smoke detector installer or dealer once
a year to ensure they are functioning correctly. It is the user’s responsibility to test the system weekly
(excluding smoke detectors). Ensure you follow all the steps in the two tests below.
NOTE: Should the system fail to function properly, call your installation company for service im-
mediately.
Sounder and Display Test
This Test activates all display pixels and indicator lights and does a four second check of the sounder.
1. Press [Master Code] .
2. The following will occur:
- The system activates the Bell output on medium volume for 2 seconds followed by full volume alarm
for 2 seconds. All display lights and LCD pixels will turn ON.
- The Ready, Armed, Trouble and Power LED’s will flash for the duration of the test
3. To exit the function menu, press .
Walk Test
Walk Test mode allows you test the operation of each detector in the system. While in Walk Test
mode, the Ready, Armed, and Trouble LED's will flash to indicate that the Walk Test is active. The
Walk Test can be terminated at anytime by re-entering [Master code] on the keypad.The
system will also automatically terminate the Walk Test on completion, it will annunciate with an audi-
ble warning (5 beeps every 10 seconds), beginning five minutes before the termination of the test.
1. Before testing, ensure that the system is disarmed and the Ready light is on.
2. Press and close all zones to return the system to the Ready state.
3. Perform a System Test by following the steps in the previous section.
4. Press [Master code] to initiate the Walk Test
5. To test the zones, activate each detector in turn (e.g., open each door/window or walk in motion
detector areas).
The System will display the following message when each zone (detector) is activated: “Secure
System Before Arming < >”, “Secure System or Enter Code” or “Secure or Arm System”. Use the
keys to view which zones are open. The message will disappear when the zones are
closed.
Allowing Computer Access To Your System
From time to time, your installer may need to send information to or retrieve information from your
security system. Your installer will do this by having a computer call your system over the telephone
line. You may need to prepare your system to receive this ‘downloading’ call. To do this:
Press [Master code] at the keypad. This allows downloading for a limited period of
time. During this time, the system will answer incoming downloading calls.
For more information on this feature, please ask your installer.