1
Section 1: System Introduction
1.1 Specifications
Downloading Software Support
PC1555MX v2.3 uses DLS-3 v1.3 and higher.
Flexible Zone Configuration
Six fully programmable zones
System expandable to 32 zones using:
up to 8 keypad zone inputs and/or
up to 32 wireless zones with the PC5132 wireless expan-
sion module
38 access codes: one master code, one maintenance
code, two duress codes, two supervision codes and 32
general access codes
27 zone types; 8 programmable zone attributes
Normally closed, single EOL and double EOL zone wiring
Audible Alarm Output
700mA supervised bell output (current limited at 3A),
12V
DC
Steady or pulsed output
EEPROM Memory
Does not lose programming or system status on complete
AC and battery failure
Programmable Outputs
One programmable voltage output and one programmable
voltage output/input; 23 programmable options
PGM1 = 50mA; PGM2 = 300mA (50/300 products)
PGM2 = 50mA; PGM2 = 50mA (50/50 products)
Eight additional low current (50mA) outputs available using
the PC5208 module
Four additional high current (300mA) outputs available
using the PC5204 module; one PC5204 output fully super-
vised for siren
Powerful 1.5 Amp Regulated Power Supply
550 mA auxiliary supply, 12 V
DC
Positive Temperature Coefficient (PTC) components
replace fuses
Supervision for loss of AC power, low battery
Internal clock locked to AC power frequency
Power Requirements
Transformer = 16.5 V
AC, 40VA
Battery = 12 volt 4Ah minimum rechargeable sealed lead
acid battery
For household fire and burglary installations, two 7Ah bat-
teries in parallel must be used, providing 24 hours of
standby power and 4 minutes of alarm output power.
For commercial burglary installations, a 4Ah (or larger) bat-
tery must be used, providing at least 4 hours of standby
power and 4 minutes of alarm output power.
NOTE: Do not install this panel outside of North America. By
design, this panel will not work if the AC line frequency drops
below 55.5Hz.
Remote Keypad Specifications
Keypads available:
- PC5502Z2 2-zone LED keypad with 2-zone inputs
- PC5506 six zone LED keypad with zone input
- PC5508Z eight zone LED keypad with zone input
- PC5516Z sixteen zone LED keypad with zone input
- PC5532Z thirty-two zone LED keypad with zone input
- LCD5500Z alphanumeric keypad with zone input
- LCD5501Z fixed message LCD keypad with zone input
- LCD5501Z32 keypad / receiver
- SL-8 Slimline 8 zone LED keypad
All keypads have five programmable function keys
Connect up to eight keypads
4-wire (Quad) connection to Keybus
Built in piezoelectric buzzer
Digital Communicator Specifications*
Supports major communication formats including SIA and
Contact ID
Digital communicator compatible receivers and their for-
mats:
Silent Knight Model 9000: 3/1, 4/1, 4/2 non-extended, 3/1
extended, 20 bps, 1400 Hz handshake.
Ademco Model 685: 3/1, 4/1, 4/2 non-extended, 3/1
extended, 20 bps, 1400 Hz handshake, Contact ID.
Sescoa Model 3000: 3/1, 4/1, 4/2 non-extended, 3/1
extended, 20 bps, 1400 Hz handshake.
Radionics Model D6500: 3/1, 4/2 non-extended, 3/1
extended, with or without parity, 1400 and 2300 Hz hand-
shake. Sur-Gard Model MLR2-DG: 3/1, 4/1, 4/2, without
parity, 20 bps, 1400 and 2300 Hz handshake, Contact ID,
SIA.
Event-initiated personal paging
Three programmable telephone numbers
Two account numbers
Supports LINKS1000 cellular communication
Supports LINKS2X50 long range radio transmitter
Supports Skyroute transceiver
DTMF and pulse dialing
DPDT line seizure
Anti-jam feature
Split reporting of selected transmissions to each telephone
number
System Supervision Features
The PC1555MX continuously monitors a number of possible
trouble conditions including:
AC power failure• AUX Power Supply Trouble
Fault by zone• Loss of internal clock
Tamper by zone• Bell output trouble
Fire trouble• Telephone line trouble
Failure to communicate• Low battery condition (panel)
Low battery by zone (wireless)
Module fault (supervisory or tamper)
False Alarm Prevention Features
Audible Exit Delay• Quick Exit
Audible Exit Fault • Cross Zone Burglary Alarm
Communication Delay• Rotating Keypress Buffer
Urgency on Entry Delay• One Restart of Exit Delay
Additional Features
Auto Arm at specified time
Keypad-activated alarm output and communicator test
All modules connect to the system via a four wire Keybus
up to 1000’/305m from main panel
An event buffer which records the past 128 events with
both the time and date at which they occurred; buffer can
be printed using PC5400 serial interface module, or
viewed with the LCD5500Z keypad and DLS-3 software
Supports the addition of the PC5132 wireless receiver for
integration of wireless devices
Uploading and downloading capability
Local downloading capability through the use of the
PC-Link adaptor
Supports the Escort5580 Voice Prompt Module with auto-
mation/lighting control
Supports the addition of the PC5928 Audio Interface Mod-
ule to integrate intercom stations
*LINKS2X50 has not been investigated by UL.