Appendix B: Programming LCD5501Z Keypads
There are several programming options available for the LCD5501Z keypad. These are described below. Record all your program-
ming choices in the programming worksheets included in this manual.
Programming Keypad Options
Programming the LCD5501Z is similar to programming the rest
of the system. To change the keypad programming:
1. Enter [*][8][Installer’s code]
2. Enter [000] to go to keypad programming
3. Enter section number [6] or [7].
4. To turn any of the options on or off, press the option number
(from [1] to [8]).
5. When you are finished programming, press [#].
When you are in the LCD5501Z programming sections, the key-
pad will display which options are turned on along the top of the
display. To turn an option on or off, press the number corre-
sponding to the option on the number pad. The numbers of the
options that are currently turned ON will be displayed.
For example, if options 1 and 2 are on, the display will look like:
Clock Options
The LCD5501Z will display the current time after 30 seconds of
no key presses. To set the correct time and date for the system,
please refer to the PowerSeries User Guide. You can change how
the keypad displays the time with options [1] to [3] in program-
ming section [6].
NOTE: If the Time does not display on keypad option is selected, make sure that the Keypad displays time when zones are open
option is also selected.
Alarms Displayed While Armed Option
You can disable the display of alarms on the keypad when the
system is armed. The display of alarms is enabled by default. To
disable the display of alarms when the system is armed, turn off
section [6], option [5].
Emergency Key Options
You can enable or disable the Fire, Auxiliary and Panic keys at
each keypad. These keys are enabled by default. Please see the
PC5010 CP-01 Installation Manual for more information on these
keys and their options. To turn any of the emergency keys on or
off on the keypad, enter section [7], and turn on or off options
[1] to [3].
Door Chime on Zone Openings/Closings
By default, LCD5501Z keypads are programmed to sound door
chimes on both zone openings and closings.
To change the door chime opening/closing settings, at each
LCD5501Z keypad, enter section [6], and turn on or off options
[6] and [7].
[6] LCD5501Z Keypad Options
Default Option On Off
ON
I________I 1 Local Clock Display Enabled Local Clock Display Disabled
ON
I________I 2 Local Clock Displays AM/PM Local Clock Displays 24-hour Time
OFF
I________I 3 Open Zones Override Clock Display Open Zones Do Not Override Clock
OFF
I________I 4 Scandinavian Approvals enabled Scandinavian Approvals disabled
OFF
I________I 5 Alarms Not Displayed While Armed Alarms Always Displayed While Armed
ON
I________I 6 Door Chime Enabled for Zone Openings Door Chime Disabled for Zone Openings
ON
I________I 7 Door Chime Enabled for Zone Closings Door Chime Disabled for Zone Closings
OFF
I________I 8 For Future Use
[7] Emergency Key Options
Default Option On Off
ON
I________I 1 [F]ire Keys Enabled [F]ire Keys Disabled
ON
I________I 2 [A]uxiliary Keys Enabled [A]uxiliary Keys Disabled
ON
I________I 3 [Panic] Keys Enabled [P]anic Keys Disabled
OFF
I________I 4-8 For Future Use