Basic Programming
7
[017] Fifth System Option Code
Default Option ON OFF
ON
I________I 1 WLS Key Does Not Use Access Codes* WLS Key Uses Access Codes
OFF
I________I 2 RF Jam Log After 5 Minutes RF Jam Log After 30 Seconds
OFF
I________I 3 Audible RF Jam Trouble Beeps Silent RF Trouble Jam Beeps
OFF
I________I 4 Double Hit Enabled Double Hit Disabled
OFF
I________I 5 Late to Close Enabled Late to Close Disabled
OFF
I________I 6 Daylight Savings Time Enabled Daylight Savings Time Disabled
ON
I________I 7 Periodic Camera Test Enabled Periodic Camera Test Disabled
OFF
I________I 8 Squawk on Away Key Arming/Disarming Only Bell Squawk on all Arming/Disarming
*This option must be enabled when using a PC5132 v2.1 or earlier. / This option is supplemental to Section 14 Option 1
[018] Sixth System Option Code
Default Option ON OFF
OFF
I________I 1 Test Transmission Exception Enabled Test Transmission Exception Disabled
OFF
I________I 2 Verbal Chime Enabled Verbal Chime Disabled
OFF I________I 3 Verbal Alarm Enabled Verbal Alarm Disabled
OFF
I________I 4 Water-Flow Silence Inhibit Enabled Water-Flow Silence Inhibit Disabled
OFF
I________I 5 Keypad Buzzer Follows Bell Enabled Keypad Buzzer Follows Bell Disabled
OFF I________I 6 Cross Zoning Enabled Cross Zoning Disabled
ON
I________I 7 Exit Delay Restart Enabled Exit Delay Restart Disabled
OFF
I________I 8 AC Trouble Beeps Enabled AC Trouble Beeps Disabled
NOTE: For Cross Zoning to function, Option[6] in Section [018] and Option [9] in Section [101]-[132] must be ON for the desired
zone. Each zone has the ability to protect the intended area. Cross Zoning is not recommended for line security installations or on
exit/entry zone types.
Keypad Zone Assignments
[020] Keypad Zone Assignments
NOTE: Only one keypad may be assigned to a zone.
Default
00 I________I_______I Keypad (slot 1) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 2) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 3) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 4) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 5) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 6) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 7) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 8) Zone Valid entries are zones 01-32
Zone Loop Response Option Code
[030] Sixth System Option Code
Default Option ON OFF
OFF I________I 1 Zone 1 is Fast Loop Response Zone 1 is Normal Loop Response
OFF
I________I 2 Zone 2 is Fast Loop Response Zone 2 is Normal Loop Response
OFF
I________I 3 Zone 3 is Fast Loop Response Zone 3 is Normal Loop Response
OFF
I________I 4 Zone 4 is Fast Loop Response Zone 4 is Normal Loop Response
OFF
I________I 5 Zone 5 is Fast Loop Response Zone 5 is Normal Loop Response
OFF
I________I 6 Zone 6 is Fast Loop Response Zone 6 is Normal Loop Response
OFF
I________I 7 Zone 7 is Fast Loop Response Zone 7 is Normal Loop Response
OFF
I________I 8 Zone 8 is Fast Loop Response Zone 8 is Normal Loop Response