DSC PC560 Instruction Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
4 9
BASIC OPERATION
Arming Your System
Before arming the system, close all protected doors and windows, and stop movement in areas protected
by motion detectors. When all zones are closed, all of the zone lights on the keypad will be OFF, and the
Ready light will be ON.
To arm the system, enter a 4-digit access code. As each digit is entered, the keypad sounder will beep.
When the access code has been entered, the Armed light will come ON and the keypad will beep 6 times.
If an incorrect access code is entered, the keypad will sound a single long tone. To correct a mistake when
entering a code, press the [#] key and enter the access code again.
When the Armed light comes ON, leave the premises through the designated entry-exit door before the exit
delay expires. At the end of the exit delay, all lights on the keypad will be shut OFF except for the Armed
light - your system is now armed.
The factory setting for the exit delay is 120 seconds; your installer may change this time to suit your needs.
Refer to the Arming Options section of this manual for information on other arming functions.
Disarming Your System
Enter the premises through the designated entry-exit door. The keypad will sound a constant tone to
indicate that the system must be disarmed.
Go to the keypad and enter an access code. If an error is made entering the code, press the [#] key and
enter the code again.
When a correct access code is entered, the Armed light will be shut OFF, and the sounder will be silenced
- your system is now disarmed.
An access code must be entered before the entry delay expires or an alarm will sound. The factory setting
for the entry delay is 30 seconds; your installer may change this time to suit your needs.
If an alarm occurred while the system was armed, the System light and the zone lights of the zones that
went into alarm will flash for two minutes. Press the [#] key to cancel the flashing display and return the
keypad to the Ready mode. Refer to “Display Alarm Memory” for instructions on displaying the zones that
went into alarm.
IMPORTANT NOTE: If you return to the premises and find that an alarm is in progress or that there
are alarms in memory, do not enter the premises as an intruder may be present. Go to a neighbour
and contact the local authorities from there.
Important Note About Keypad [
] Commands
The [
] commands described in this manual allow you to access various system functions and features. It is
important that all users of the system know that the [
] commands will not function while the bell or siren is active.
If an alarm is sounding, an access code must first be entered to silence the alarm before the [
] functions can
be used.
DISPLAYING SYSTEM INFORMATION
Display Alarm Memory
Alarms generated when the system is armed are recorded in the system’s memory. To display the zones
that went into alarm, enter [
][3]. The System light will flash, and the zones that went into alarm will be
displayed on the flashing zone lights. Note that the alarm memory will be cleared the next time the system
is armed.
Display Trouble Conditions
The PC560 constantly monitors itself to ensure proper operation. When a condition occurs that could
affect operation, the System light will come ON and the keypad will sound two short beeps every 10
seconds to warn of the trouble condition.
To silence the sounder, press the [#] key. The keypad will be silenced, but the System light will remain
ON until the trouble condition is cleared.
To display the trouble conditions, enter [
][2]. Trouble conditions are represented with the zone lights; if a
zone light comes ON, then that trouble condition is present:
Zone Light Trouble Cause What To Do
1 Battery Trouble Battery is low or disconnected Call for service
2 AC Failure AC power is out Check your fusebox or
circuit breakers; call for
service if the trouble
condition cannot be
corrected
4 Communications System cannot communicate Call for service if trouble
Trouble with monitoring station does not correct itself
Note that the keypad sounder will
not
beep if only the AC Failure trouble is present.
Page view 10