11
Zone Bypassing
The zone bypassing function is used when access is needed to part of the protected area while the
system is armed. Zones which are temporarily out of service due to damaged wiring or contacts may
be bypassed to allow system arming until repairs can be made.
Bypassed zones will not cause an alarm. Zones cannot be bypassed once the system is armed.
Bypassed zones are automatically cancelled each time the system is disarmed and must be reapplied
before the next arming.
NOTE: For security reasons, your installer may program the system to prevent you from
bypassing certain zones.
Bypassing zones reduces your security protection. If you are bypassing a zone due to damaged
wiring or contacts, please call a service technician immediately so that the problem can be
resolved and your system returned to proper working order.
Make sure that no zones are unintentionally bypassed when arming your system.
To bypass zones from an LED keypad:
Start with the system in the Ready state. Enter [][1][Zone(s) to be bypassed].
Enter the zone(s) as a two-digit number from 01 to 32. As each zone is bypassed, the corresponding
zone light will turn ON. If a zone is bypassed by mistake, enter that zone number again; the zone light
will turn OFF, indicating that the zone is not bypassed. Press [#] to return to the Ready state.
To bypass zones from an LCD keypad:
To bypass a zone, the system must be in the Ready state. The display will read...
Press the [] key to enter the functions menu. The display will read...
Press the [] key to enter the zone bypassing mode. The display will read...
Use the arrow (< >) keys to find the zone to be bypassed and press the [
] key to
select it. The display will read...
“B” will appear on the display to show that the zone is bypassed. To unbypass a
zone, enter the zone number; the “B” will disappear from the display to show that
the zone is no longer bypassed.
This display will be shown if a zone was open when you entered the bypassing
command. The open zone will be represented by “O”. If you bypass the open zone,
the “O” will be replaced by a “B”.
To exit the bypassing mode and return to the Ready state, press the [#] key.
Viewing Trouble Conditions
The control panel continuously monitors a number of possible trouble conditions. If one of these
trouble conditions occur, the keypad will beep twice every 10 seconds until you press any key on the
keypad.
NOTE: A TROUBLE condition reduces the security your system is designed to provide. Call your
installing company for service.
Enter Code to
Arm System
Press (*) for <>
Zone Bypass
Zone Search <>
“Zone Name”
Zone Search <>
“Zone Name” B
Zone Search <>
“Zone Name” O
Page view 12